SKU
FO20M1-8-73

Categories

Latest Products

Brand:

Flaax – CST 8C FO Cable – Multimode OM1 62.5/125 – LSZH-UV CPR:B2ca (Orange)

3000N,Ind/Out, Class B2ca-s1a-d1-a1, gel-filled, water-blocked central tube cable, up to 24 fibres, glass yarn, steel tape armouring and FireRes®sheath. DIN/VDE:U-D(ZN)(SR)H
  • FO cable with central loose tube filled with gel for structured cabling.
  • The cable is UV-resistant, with steel tape armoring, longitudinally water blocked and rodent-protected with a tensile strength of 3.0kN.
  • The jacket is made of halogen-free, flame-retardant material according to IEC60332-1; IEC60332-3-24; IEC60754-1/2; IEC61034;
  • EN50399 for use in public buildings with high personal risk and higher Euro fire class B2ca s1a D1 a1.
  • Fire resistant cable Circuit Integrity according to IEC 60331-25 and EN 50200 PH120.
  • Use outdoors for duct installation and as a flame-retardant cable indoors.
  • The fiber optic cable exceeds the requirements of EN50173-1, ISO/IEC11801 and EN/IEC60794-6

Share:

Description

CERTIFICATIONS AND DESIGN STANDARDS
• EN 50399 Class B2ca-s1a-d1-a1
• ISO/IEC 11801 Generic telecom cabling for
customer premises
• EN 50173 Information technology – Generic cabling
systems
• IEC 60332-1-2 Single wire fire test
• EN 50200 Fire resistance at 830ºC during 120min +
mechanical impacts
• IEC 60331-25 Fire resistance at 750ºC during
120min + 15min cooling down
• IEC 60332-3-24 Bundled fire test• EN 50575 Cables in construction works subject to
reaction to fire
• IEC 60794-1-1 Generic Specification Fibre Optic
Cables
• IEC 60794-1-21 Mechanical Test Methods
• IEC 60794-1-22 Environmental Test Procedures
• IEC 60754-1 Toxicity
• IEC 60754-2 Weighted Values of pH and
Conductivity
• IEC 61034-2 Smoke Density
APPLICATION PROPERTIES
Resistant to UV UV stabilised
With rodent protection Yes with corrugated steel tape for rodent protection
Permitted cable outer temperature after assembling without vibration (min) [°C]* -40 (max) [°C] 70
Permitted cable outer temperature during assembling/handling (min) [°C]* -40 (max) [°C] 70
Outdoor installation Yes
Suitable for installation in cable ducts, on cable trays
Bending radius (rule) During installation (loaded) = 20xOD, Permanent (unloaded) = 10xOD
CABLE CONSTRUCTION
Cable marking Sequentially meter marked FLAAX “Product SKU” 8COM162.5/125 FO “Metre Marking”
Longitudinal water blocking cable Yes
Radial water blocking cable Yes
Armouring/reinforcement Copper wires, separator tape, steel tape
Armouring/reinforcement material Steel, uncoated
Material outer sheath Low smoke zero halogen
Type of tube Central tube
Cable shape Round
With rodent protection Yes
Multimode OM1 62.5/125
Central tube Gel filled
Waterproof Both longitudinally and transversely

Flame retardancy acc. to IEC 60332-1-2 and IEC 60332-3-22 Cat. A
Smoke density acc. to IEC 61034
Halogen-free acc. to IEC 60754-2
Test under fire conditions IEC 60331-11 /-25; 90 minutes
Circuit integrity EN 50200: 2000 Class PH120 (120 minutes) & BS 8434:2003 Part 2

DIN VDE 0888, Part 100-2 (DIN EN 60794-1-2:2004)
IEC 60794-1-2-E1 test method E1 Pull force
IEC 60794-1-2-E3 test method E3 Crush resistance
IEC 60794-1-2-E4 test method E4 Impact
IEC 60794-1-2-E7 test method E7 Torsion
·IDINVDE0888,Part100-2(DINEN60794-1-2:2004)EC 60794-1-2-F1 test method F1 Temperature change

IEC 60794-1-2-E1 test method E1: pull force
· IEC 60794-1-2-E3 test method E3: crush resistance
· IEC 60794-1-2-E4 test method E4: impact
· IEC 60794-1-2-E7 test method E7: torsion
· IEC 60794-1-2-F1 test method F1: temperature change

Emits no corrosive and toxic fumes

Additional information

Weight 0.0 kg
Dimensions 0.0 × 0.0 × 0.0 cm

Related Products